Home PICO | Data Loggers Thermocouple high-temp type K exposed tip, fiberglass insulated, 5 m
PICO | Data Loggers

Thermocouple high-temp type K exposed tip, fiberglass insulated, 5 m

Precision You Can Trust
NABL-Accreditied Calibration | Available on Request

The Pico SE062 High-Temperature Type K Thermocouple is an exposed-junction sensor designed for oven, laboratory and industrial high-temperature measurements. It features a 5 m fiberglass-insulated cable, a 0.8 mm conductor rated to +1000 °C, insulation suitable for continuous operation at +750 °C, and Class 1 Type K performance of ±1.5 °C over −40 °C to +1000 °C..

  • Detail
  • Special Features
  • Specification

The Pico SE062 High-Temperature Type K Exposed-Tip Thermocouple, Fiberglass Insulated, 5 m is designed for engineers, research laboratories and industrial testing applications that require high-temperature measurement combined with extended cable reach.

Pico Technology identifies the SE062 as the 5 metre model in its high-temperature Type K thermocouple range. It uses an exposed sensing junction, high-temperature glass-fiber insulation and a 0.8 mm thermocouple conductor.

Key manufacturer specifications include:

  • Order Code: SE062
  • Thermocouple Type: Type K
  • Junction Type: Exposed
  • Accuracy Class: Class 1
  • Pico-Quoted Accuracy: ±1.5 °C
  • Quoted Class 1 Range: −40 °C to +1000 °C
  • Cable Length: 5 m
  • Conductor Diameter: 0.8 mm
  • Conductor Temperature Rating: Up to +1000 °C
  • Insulation: High-temperature fiberglass / glass fiber
  • Continuous Insulation Rating: +750 °C
  • Primary Application: Oven and high-temperature temperature measurement

High-Temperature Type K Measurement

The SE062 uses Type K thermocouple technology, widely used for industrial, laboratory and engineering temperature measurements.

Pico specifies its Class 1 performance over:

  • −40 °C to +1000 °C

The 0.8 mm thermocouple conductor is also rated for temperatures up to:

  • +1000 °C

This makes the SE062 suitable for applications where standard low-temperature thermocouple assemblies may not provide sufficient temperature capability.

Class 1 Accuracy

Pico specifies the SE062 as a Class 1 Type K thermocouple with:

  • Accuracy: ±1.5 °C
  • Quoted range: −40 °C to +1000 °C

Pico thermocouples are manufactured to recognized industry tolerances stated in:

  • IEC 60584-2:1993
  • BS EN 60584-1:2013

The final accuracy of a complete temperature-measurement system also depends on the data logger, cold-junction compensation, installation and thermocouple condition.

High-Temperature Fiberglass Insulation

The SE062 uses high-temperature glass-fiber insulation designed for continuous operation at:

  • +750 °C

This value should be clearly distinguished from the +1000 °C conductor rating.

The cable insulation is rated for continuous +750 °C operation, while the thermocouple conductor itself is rated to +1000 °C.

0.8 mm High-Temperature Conductor

Pico specifies a:

  • 0.8 mm thermocouple conductor

The conductor is suitable for temperatures up to:

  • +1000 °C

This high-temperature construction differentiates SE062 from Pico's standard SE031 5 m fiberglass-insulated Type K thermocouple, which uses a thinner 0.3 mm conductor and has a lower temperature rating.

Exposed-Junction Temperature Measurement

The SE062 uses an exposed thermocouple junction.

The sensing junction is directly exposed to the measurement environment rather than being enclosed in a protective metal sheath.

This reduces thermal mass around the sensing junction and makes exposed-tip thermocouples useful where responsive temperature measurement is required.

Typical applications include:

  • Oven air-temperature measurement
  • Heated gas monitoring
  • Thermal chamber testing
  • Heating-cycle measurement
  • Laboratory thermal experiments
  • High-temperature R&D

Suitable for Gas and Air Measurements

Exposed-tip thermocouples are particularly useful for suitable air and gas-temperature measurements because the sensing junction directly contacts the surrounding medium.

Potential applications include:

  • Oven atmosphere monitoring
  • Heated-air systems
  • Laboratory gas measurements
  • Thermal chambers
  • Engineering heating experiments

A numerical response time should not be added unless Pico publishes a specific value for SE062.

Limitation for Corrosive or Oxidizing Liquids

Because the thermocouple junction is exposed, this probe should not be treated as a general-purpose liquid-immersion sensor.

For corrosive, chemically aggressive or oxidizing liquids, an appropriately protected or sheathed thermocouple should be selected.

5 m Extended Cable Length

The SE062 provides:

  • Cable Length: 5 m

The extended cable is useful where the measurement point needs to remain several metres away from the temperature data logger.

Typical installations include:

  • Large industrial ovens
  • Thermal chambers
  • Heat-treatment equipment
  • Laboratory furnaces
  • Remote temperature-measurement points
  • Large test fixtures

The longer cable can help keep the measurement instrument outside the high-temperature area.

Pico High-Temperature Type K Range

Pico offers the same high-temperature construction in several cable lengths:

Model Cable Length
SE059 1 m
SE060 2 m
SE061 3 m
SE062 5 m

All four are high-temperature, exposed-tip, fiberglass-insulated Type K thermocouples.

The appropriate model can therefore be selected according to the required distance between the measurement point and data logger.

Fixed High-Temperature Installation

Pico specifically notes that high-temperature performance is particularly suitable when the thermocouple is fixed in position and the fiberglass insulation is not repeatedly flexed.

For high-temperature applications:

  • Keep cable routing stable
  • Avoid unnecessary flexing when the insulation is hot
  • Prevent mechanical abrasion
  • Keep the exposed junction correctly positioned
  • Respect the +750 °C continuous insulation rating
  • Avoid contamination of the sensing junction

The 5 m cable should therefore not be marketed simply as providing unrestricted flexibility at extreme temperatures.

Ideal for Oven Temperature Measurement

Pico specifically describes the SE062 construction as suitable for oven temperatures.

Typical oven applications include:

  • Oven temperature profiling
  • Heating-cycle monitoring
  • Cooling-cycle monitoring
  • Temperature distribution testing
  • Process-development experiments
  • Product heat testing
  • Laboratory oven validation
  • Quality-control measurements

Thermal Chamber Testing

The SE062 can support high-temperature measurement in suitable thermal and environmental chambers.

Multiple thermocouples can be placed at different locations to monitor:

  • Temperature uniformity
  • Hot and cold zones
  • Heating rates
  • Cooling rates
  • Thermal gradients
  • Process stability

Heat-Treatment and Materials Testing

The high-temperature conductor and extended cable length make SE062 useful for suitable applications involving:

  • Heat-treatment testing
  • Materials research
  • Product thermal validation
  • High-temperature R&D
  • Industrial heating processes
  • Laboratory experiments

The measurement arrangement should always remain within the temperature ratings of the conductor and insulation.

Recommended for Pico USB TC-08

Pico Technology lists the SE062 as a recommended accessory for the USB TC-08 Thermocouple Data Logger.

The TC-08 provides:

  • 8 thermocouple input channels
  • Type K support
  • Built-in cold-junction compensation
  • Multi-channel temperature logging
  • PicoLog software support
  • Long-duration recording

Multiple SE062 sensors can therefore be connected to available TC-08 channels for multi-point high-temperature monitoring.

Multi-Point High-Temperature Logging

Using several thermocouples with a multi-channel logger can help engineers compare:

  • Temperatures at different locations
  • Heating rates
  • Cooling rates
  • Thermal gradients
  • Temperature distribution
  • Process temperatures over time

This is particularly useful in ovens, thermal chambers and product-validation applications.

Thermocouple Aging at High Temperature

Prolonged exposure to high temperatures can gradually affect thermocouple performance.

Potential influences include:

  • Thermocouple alloy changes
  • Contamination
  • Oxidation
  • Mechanical damage
  • Fiberglass insulation degradation

For demanding applications, periodically inspect the thermocouple and replace it if physical or measurement performance deteriorates.

Typical Applications

The Pico SE062 is suitable for:

  • Oven temperature monitoring
  • High-temperature air measurement
  • Gas-temperature measurement
  • Thermal chamber testing
  • Heat-treatment experiments
  • Laboratory furnace testing
  • Materials research
  • Industrial thermal process monitoring
  • Product heat testing
  • Engineering R&D
  • Temperature profiling
  • Multi-point TC-08 temperature logging

High-Temperature Type K Thermocouple

The SE062 is designed specifically as a:

  • High-temperature Type K thermocouple

Its conductor is rated for temperatures up to:

  • +1000 °C

Class 1 Performance

Pico specifies:

  • Accuracy Class: Class 1
  • Quoted Accuracy: ±1.5 °C
  • Quoted Range: −40 °C to +1000 °C

These values should replace the unsupported ±1.1 °C / ±0.4% figures currently shown on the RevineTech page.

0.8 mm Conductor

The SE062 uses a:

  • 0.8 mm thermocouple conductor

The conductor itself is suitable for temperatures up to:

  • +1000 °C

High-Temperature Fiberglass Insulation

The cable uses:

  • High-temperature fiberglass / glass-fiber insulation

Pico specifies the insulation for:

  • Continuous operation at +750 °C

Exposed Sensing Junction

The SE062 uses an:

  • Exposed thermocouple junction

This provides direct contact between the thermocouple junction and the measurement environment.

Responsive Air and Gas Measurement

The exposed-junction construction is suitable for responsive measurement of compatible air and gas environments.

It avoids the additional thermal mass associated with a metal-sheathed sensing junction.

5 m Extended Cable

The SE062 provides:

  • 5 m cable length

This is the longest standard cable option in Pico's current SE059 to SE062 high-temperature Type K family.

Suitable for Remote Measurement Points

The extended 5 m cable can help separate the measurement instrument from:

  • Ovens
  • Hot chambers
  • Industrial heating systems
  • Test fixtures
  • High-temperature process areas

Designed for Oven Temperatures

Pico specifically identifies the construction as:

  • Ideal for oven temperatures

This is a manufacturer-supported application and should replace broad unsupported claims about generic extreme industrial environments.

Suitable for Fixed High-Temperature Installations

Pico notes that the thermocouple can withstand demanding temperatures when:

  • The cable remains fixed
  • The fiberglass insulation is not repeatedly flexed

This is an important installation consideration for long-term high-temperature applications.

Industry Thermocouple Standards

Pico thermocouples are manufactured to tolerances stated in:

  • IEC 60584-2:1993
  • BS EN 60584-1:2013

Recommended USB TC-08 Accessory

Pico officially lists SE062 as a:

  • Recommended USB TC-08 accessory

This provides manufacturer-confirmed compatibility for Type K multi-channel temperature logging.

SE062 vs SE031 Standard 5 m Thermocouple

Feature SE062 High Temperature SE031 Standard
Thermocouple Type Type K Type K
Junction Type Exposed Exposed
Cable Length 5 m 5 m
Conductor Diameter 0.8 mm 0.3 mm
Insulation High-temperature fiberglass Standard glass fiber
Class / Accuracy Class 1, ±1.5 °C Industry thermocouple tolerance
Temperature Capability Class 1 quoted to +1000 °C Tip rated −60 °C to +350 °C
Continuous Insulation Rating +750 °C Not specified at SE062 level
Primary Use High-temperature / oven measurement General-purpose temperature logging

For the current RevineTech high-temperature 5 m product, SE062 is the correct model, not SE031.

Manufacturer Pico 
Model / Order Code SE062
Product Name Thermocouple High-Temperature Type K, Exposed Tip, Fiberglass Insulated, 5 m
Product Type High-Temperature Exposed-Junction Thermocouple
Thermocouple Type Type K
Accuracy Class Class 1
Pico-Quoted Accuracy ±1.5 °C
Quoted Class 1 Range −40 °C to +1000 °C
Junction Type Exposed
Conductor Diameter 0.8 mm
Conductor Temperature Rating Up to +1000 °C
Insulation Material High-temperature fiberglass / glass fiber
Continuous Insulation Rating +750 °C
Cable Length 5 m
Recommended Application Oven and high-temperature measurements
Air / Gas Measurement Suitable exposed-junction configuration
High-Temperature Installation Best suited to fixed positioning without repeated insulation flexing
Tolerance Standards IEC 60584-2:1993 / BS EN 60584-1:2013
TC-08 Compatibility Recommended accessory
Primary Applications Oven testing, thermal chambers, gas-temperature measurements, heat-treatment testing and high-temperature data logging
Live in Bengaluru electronica India 2026 · Sept 16 to 18 · BIEC Booth H3.J15, Hall 3 Loading... Book a meeting